This is a public Discussion Area  publicRSS

Thread

    Backup Startup Config FAILED to run. An appropriate script...
    Thread posted Jan 20 by Tobias Feichtinger
    384 Views, 2 Comments
    Title:
    Backup Startup Config FAILED to run. An appropriate script for this task could not be found.
    Content:

    Hi

    I have got installed the new configured plugin at our Whatsup.(V14.1.2)

    I added the default Backup Script to one Cisco 3750 Switch and it dosent work.

    I get the following error.

    Backup Startup Config FAILED to run. An appropriate script for this task could not be found.

    I have downloaded the Cisco CDP Script and this works normaly. So there must be an error with the pre definied script.

    Some idea?

    Greeds

    Tobias Feichtinger

    Comments

    • posted Feb 4 by Simon Brecht

      Hi Tobias,

      please check the snmp device object id in "device properties"->"credentials". This must exactly match on a cisco device to use the default backup script.


      Regards,
      Simon

    • posted Feb 9 by Tobias Feichtinger

      Hi Simon.

      Thanks for this Information. And it looks like this was the missing Part.

      I have added the Switches without scanning them.

      Greeds Feichti